Auerswald COMpact 5010
From VoIP.ms Wiki
| [draft revision] | [quality revision] |
| Line 16: | Line 16: | ||
'''Note:''' | '''Note:''' | ||
| - | |||
| - | |||
| - | |||
| + | * The (internal) SIP port set by the box, each configuration for a provider has it's own port | ||
| + | * The shown codec setting works only if G.711 and G.729 are selected in the portal, otherwise you have to select only these two codecs in the PBX configuration | ||
| + | * Format der eigenen Rufnummer (own number): With this setting, the PBX will send the correct caller ID. | ||
| - | [[File:Auerswald 5010 1.jpg| | + | |
| + | [[File:Auerswald 5010 1.jpg|1000px]] | ||
| Line 30: | Line 31: | ||
Select the provider that you have entered on Step 1 (Voipms), then under Kind of Connection select PTMP Connection, finally click the button Configure. | Select the provider that you have entered on Step 1 (Voipms), then under Kind of Connection select PTMP Connection, finally click the button Configure. | ||
| - | [[File:Aureswald 5010 2.png| | + | [[File:Aureswald 5010 2.png|1000px]] |
Now on the following screen, set the following. | Now on the following screen, set the following. | ||
| Line 56: | Line 57: | ||
'''Ringer rhythm:''' Optionally, you can select the ringer rhythm that should be used for the MS | '''Ringer rhythm:''' Optionally, you can select the ringer rhythm that should be used for the MS | ||
| - | [[File:Aureswald 5010 3.png| | + | [[File:Aureswald 5010 3.png|1000px]] |
Revision as of 14:41, 2 April 2013
After you have logged in to your device configuration screen, please enter the following information.
Configuration Details
Step 1
Under Voice Over IP (VoIP) >> Providers, enter the following:
Domain: london.voip.ms (Replace with the address of one of the multiple servers from VoIP.ms)
Registrar: london.voip.ms (Replace with the address of one of the multiple servers from VoIP.ms)
Port: 5060
Note:
- The (internal) SIP port set by the box, each configuration for a provider has it's own port
- The shown codec setting works only if G.711 and G.729 are selected in the portal, otherwise you have to select only these two codecs in the PBX configuration
- Format der eigenen Rufnummer (own number): With this setting, the PBX will send the correct caller ID.
Step 2
Under the next tab Voice Over IP (VoIP) >> Accounts, enter the following:
Select the provider that you have entered on Step 1 (Voipms), then under Kind of Connection select PTMP Connection, finally click the button Configure.
Now on the following screen, set the following.
Account Name: The name that was chosen in Setup Account 1
Country Prefix: E.g. 001 for NAMP or 01141 for Switzerland
Area code: 201 for New York
Country: Technically the country that correspondence with the country prefix, however there is a back in this version of the firmware and only "Germany" can be chosen. It does not have any effect on the functionality
Exchange line access number (account number): The internal number in the PBX for this account. Can be used to dial-out directly and override the set up for external line preference
User name: 100000 (your VoIP.ms username)
Password: ********* (account password)
Authorization ID: Can be left blank
Multiple subscriber numbers (MSNs): The phone number(s) chosen/assigned by VoIP.ms
Display name: Assign a unique display name (16 characters max.) for the MSN
Ringer rhythm: Optionally, you can select the ringer rhythm that should be used for the MS