Grandstream HT802v2 - VoIP.ms Wiki

Check out our YouTube channel to watch our simple tutorials that will help you set up most of our features.

Grandstream HT802v2

From VoIP.ms Wiki

Revision as of 17:21, 15 August 2025 by Scomtois (Talk | contribs)
Jump to: navigation, search

📖 VoIP.ms Grandstream HT802 V2 Setup Guide

Contents

Overview

This guide walks you through configuring a Grandstream HT802 V2 with VoIP.ms. It supports: - Voice service - Fax (T.38 or G.711 pass-through)

Requirements

  • Grandstream HT802 V2
  • Latest firmware installed (Grandstream site) (We you use firmware version 1.0.5.7 or later.)
  • VoIP.ms account with a configured DID and a sub-account
  • Internet access via Ethernet
  • Phone or fax device connected to FXS Port 1

Logging into the Web Interface

Connect the HT802 to your network and power it on.
  • Pick up the connected phone, dial:
  • ***02 (Star Star Star 0 2)

The ATA will read its IP address. Open a browser and go to that IP (e.g., http://192.168.1.50).

Login
  • Username: admin
  • Password: found on device label (or as set by you)

General Settings (FXS PORT1)

  • Account Active: ✅ Checked
  • Primary SIP Server: popserver.voip.ms (or your nearest VoIP.ms POP)
  • Failover SIP Server _Optional: backup POP_ from a different POP location.
  • Prefer Primary SIP Server Yes
  • SIP User ID Your VoIP.ms sub-account username
  • SIP Authenticate ID Same as SIP User ID
  • SIP Authentication Password Your sub-account password
  • NAT Traversal Keep-Alive (recommended)
Click Save and Apply.

SIP Settings Tab

  • Register Expiration: 120 seconds
  • Enable SIP OPTIONS Keep Alive: Yes
  • Local SIP Port: 5060 (change if multiple ATAs)
Disable extra headers:
  • Privacy Header → No
  • P-Preferred-Identity Header → No
  • P-Access-Network-Info → No
  • P-Emergency-Info → No

Codec Settings Tab

Preferred Vocoder (in all sessions): G722, (G.711 μ-law) then set G711 for the rest.

Advanced Settings

Check SIP User ID for Incoming INVITE: Enabled
Allow incoming SIP messages from SIP proxy only: Enabled
FXS Port1 Advanced Settings.png

Faxing

Ensure options like Enable‑Call‑Waiting, Caller‑ID, and Tone are unchecked — avoiding disruptions during fax sessions.
Security Settings: Enable Allow incoming packets from SIP proxy only to restrict access to VoIP.ms servers.
Under Call Settings
Disable Local Call Features: Yes
  • Enable-Call-Waiting: uncheck
  • Enable-Call-Waiting-Caller-ID: uncheck
  • Enable-Call-Waiting-Tone: uncheck
Under Call Features Settings:
  • Set Enable Local Call Features No to prevent unintended feature code usage via the fax machine.
FXS Port1 Call Freatures Settings.png
Under Codec Settings:
  • Fax Mode: T.38 (if you are using it for faxing with a VoIP.ms FAX POP server)
  • T.38 Max Bit Rate: 14400 bps
  • Jitter Buffer: Fixed, High
Under Analog Signal Line Configuration
  • Enable Line Echo Canceller (LEC) → Check

Testing

Reboot the ATA after applying settings.
Check Status tab → Registration should be Yes.
Dial: 4443 for a Voice Echo Test.
Personal tools
Namespaces
Variants
Actions
VoIP.ms Wiki
Guides 🇨🇦