Beronet
From VoIP.ms Wiki
BeroNet is Europe's leading manufacturer of ISDN, Analog, Hybrid and GSM VoIP access technologies. The following section describes the configuration to configure a VoIP.ms SIP Trunk on a beroNet VoIP gateway.
Contents |
To start, please login into your BeroNET VoIP Appliance.
SIP General Settings
SIP General
You will need to adjust the RTP Port Range under "SIP General Options" settings to this value.
Bind Port: 5060
RTP Port Range: 10000-20000
TOS RTP: 160
TOS SIP: 160
Reject Calls under load: [unchecked]
RTP Port section: standard
Emergency Numbers: Enter the emergency numbers like 911. Each numbers needs to be separated by " | "
SIP transport: udp
Determining on how or where, you will use your beroNet VoIP gateway, you will probably need to add into your firewall/router a "port forwarding rules" for the SIP Bindport "5060" and also for the Audio packet RTP Range "10000-20000".
SIP Account
To be able to connect your VoIP.ms SIP account, you will need to create a SIP Trunk. To do so, go to the top navigation menu and click on "SIP+".
Once you are at the "SIP CONFIGURATION" page, you will need to add a new trunk by clicking on the "Add" button.
Sip Configuration
At this part, you will need to enter the information of your VoIP.ms account.
- Name: VoIPms (Or the name of your choice)
- Server Address: Your preferred VoIP.ms Server
- User: Your sub account username
- Authentification user: Your sub account username
- Secret: Your sub account password
- Displayname: Is your Outbound Caller ID Name (Usualy not exced 15 caracters for Landline caller ID Display)
- SIP Transport: You need to choose UDP
- NAT options: Use the option by default No-NAT.
- Register: Check the box
Advanced SIP Settings (More)
Under the menu "more" you don't have to change anything because the default settings of the gateway are ok.
Finally, you need to set your the country and your city code, under provider settings For example, the configuration is for american Canada/USA)
Country Code: 1 (e.g. for USA)
City Code: You will enter your NPA (e.g. NPA-NXX-XXXX > 555-123-1234)
Gateway Configuration
Hardware Settings
For this part, you will need to .To do so, on the navigation bar, click on "Hardware". You will access to all parameters of your current hardware.
Now, you have to set the PRI to NT mode by modifing the Type settings. (The settings is the same for BRI ports). Likewise set the "Clock mode" to InernalCrystal".
Set the ISDN Port Groups
In this part, you will need to create a new group for your PRI and give them the proper name. To do so, navigate to the navigation bar and select under the menu "PSTN+", select "ISDN PRI".
Dialplan configuration
FAX
You will be able to use Fax over G.711 as well as is using the T.38 protocol with your fax if your sub account is linked on it. Please note that the T.38 Faxing is currently in BETA Testing Phase.
Please refer to our Wiki Virtual Fax T.38 page to know how to link a Fax to a sub account.
CLIP / CLIP No Screening
VoIP.ms Trunks support "CLIP No Screening" which means you can present any number as outbound caller ID, regardless if it’s associated with your account or not.
For this to work, in the Outbound Caller ID can be set, the numbers must be input in either a 10-digit (e.g. 6471234567), 11-digit format (e.g. 16471234567) or E164 format (e.g. +16471234567).
If your caller id it set direclty by your sub account, in your VoIP.ms customer portal. No matter what callerid you specify in your BeroNET VoIP gateway SIP settings, the CallerID Number will be the one indicated in the sub account. In this case, you will need to remove the Outbound CallerID Number from your sub account in your VoIP.ms customer portal.
Other
If the configuration is not working with the version 15 of your BeroNET VoIP Gateway, you will need to upgrade de firmware to the version 16.15 or higher.