beroNet is Europe's leading manufacturer of ISDN, Analog, Hybrid and GSM VoIP access technologies. The following section describes the configuration to configure a VoIP.ms SIP Trunk on a beroNet VoIP gateway.

Contents


To start, you will need to validate the version of your beroNet Gateway, it's need to be at the firmware version 16.15 or higher.

We will show you the configuration for a base on an ISDN-PBX with PRI/BRI interfaces who's connected to a BeroNet gateway, we will explain you how to link a VoIP.ms SIP-Trunk.


Connection Settings SIP Trunk

You will need the following settings from your VoIP.ms account.

- SIP outbound proxy: - SIP registrar: Your VoIP.ms server - SIP domain: Your VoIP.ms server - User: SIP username from your sub account - Secret: Your sub account password - The SIP Transport-Procol is UDP


SIP General Settings

To be able to connect your SIP Account, you will need to create a SIP Trunk. To do so, go to the top navigation menu and clic on "SIP+".

Once you are at the "SIP CONFIGURATION" page, you will need to add a new trunk by clicking on "Add"

On the top menu SIP, "SIP General Options" you can modify general SIP-Account Settings.


 Depending on how/where you are going to use the beroNet gateway, you will need to add "port forwarding rules" on your Route for the SIP Bindport 5060 and the Audion RTP Range 10000-20000.

To start, please login into your BeroNET VoIP Appliance.


BeroNET login.png

SIP Account

BeroNET SIP.png


BeroNET SIP Manual.png


BeroNET SIP Config.png

Advanced SIP account Settings

BeroNET SIP Config More.png


Under the menu "more" you don't have to change anything because the default settings of the gateway are ok.

Nevertheless I will explain some settings because they are important to understand if something has to be changed.

The SIP-Header "From-Display" should contain the outgoing CalledID and has to be changed to "new_source" while the From_User_Part has to be changed to account_username.


From User Part = account_username
From Display Part = new_source


Dialplan_Source is set by default to from_display and don't have to be changed.

Dialplan_Source = from_display


Finally we have to set the Country and City Code, as well as the International prefix, for instance the settings for Germany Berlin are:

International Code: 011 (without trailing 00) National Code: 1 (without trailing 0) International prefix 00


Furthermore you can choose the Destination and Source Number Format. Deafult is 00 (int) (nat) (num)


Hardware Settings

Under the menu "Hardware" you can find all settings in regards to the hardware you are using. Set the PRI to NT mode by modifing the Type settings. Same applies to BRI ports. Furthermore set the "Clock mode" to InernalCrystal".



ISDN Port Groups

Dialplan configuration

BeroNET Dialplan.png

BeroNET Dialplan Add VoIPms.png

BeroNET Dialplan Added.png

FAX

CLIP / CLIP No Screening

Namespaces
Variants
Actions